Temperature range (3000 hours): -40℃ to +105℃ Construction/Materials: Conductor: Soft-annealed electrolytic copper conforming to DIN EN 13602, bare conductor or tinned according to the requirements of ISO 6722 standard. Soft PVC, performance compliant with ISO 6722-1 standard, Class B. Standards/Specifications: BMW GS 95007-1-1 · VW 60306-1 · DBL 6312 Ford ES-AU5T-1A348 · LV 112-1 · MAN 3135 BOSCH 5 998 340 · FIAT 91107/18

Still hesitating? Just get a sample and contact us!

  • Product Details
  • Product Name
    PRODUCT Name

     

    FLRY Thin-walled polyvinyl chloride insulated (Type A/B)

     

    Product Applications
    PRODUCT APPLICATION

     

    Low-temperature automotive wires primarily use PVC as their insulating material. They are used in the ambient-temperature areas of automotive wiring harnesses.

     

    Technical Parameters
    Technical parameter

     

    Temperature range (3000 hours) -40℃ to +105℃
    Structure/Material:
    Conductor: Soft-annealed electrolytic copper conforming to DIN EN 13602, bare conductor or tinned, meeting the requirements of ISO 6722 standards.
    Soft PVC, performance compliant with ISO 6722-1 standard, Class B
    Standards/Specifications: BMW GS 95007-1-1 · VW 60306-1 · DBL 6312
    Ford ES-AU5T-1A348 · LV 112-1 · MAN 3135
    BOSCH 5 998 340 · FIAT 91107/18

     

    Cross-sectional area Conductor Construction Insulation Wire
    Number of conductor strands Conductor outer diameter
    Maximum value
    Stranded outer diameter
    Maximum value
    Conductor at 20℃
    DC resistance
    Thick skin Outer diameter Approximate weight
    Maximum value Tolerance
    square millimeters   mm mm mΩ/m mm mm mm kg/km
    FLRY – Type A
    0.22 7 0.21 0.7 84.8/86.5 0.2 1.2 –0.1 3
    0.35XX 7 0.26 0.8 54.4/55.5XX 0.2 1.3 –0.1 5
    0.5 19 0.19 1 37.1/38.2 0.22 1.6 –0.2 7
    0.75 19 0.23 1.2 24.7/25.4 0.24 1.9 –0.2 9
    1 19 0.26 1.35 18.5/19.1 0.24 2.1 –0.2 11
    1.25 19 0.3 1.7 14.9/15.9 0.24 2.3 -0.2 15
    1.5 19 0.32 1.7 12.7/13.0 0.24 2.4 –0.2 16
    2 19 0.38 2 9.42/9.69 0.28 2.8 –0.3 22
    2.5 19 0.41 2.2 7.6/7.82 0.28 3 –0.3 26
    FLRY – Type B
    0.35 12 0.21 0.9 54.4/55.5XX 0.2 1.4 –0.2 5
    0.5 16 0.21 1 37.1/38.2 0.22 1.6 –0.2 7
    0.75 24 0.21 1.2 24.7/25.4 0.24 1.9 –0.2 9
    1 32 0.21 1.35 18.5/19.1 0.24 2.1 –0.2 11
    1.25 16 0.33 1.7 14.9/15.9 0.24 2.3 -0.2 14
    1.5 30 0.26 1.7 12.7/13.0 0.24 2.4 –0.2 16
    2 28 0.31 2 9.42/9.69 0.28 2.8 –0.3 23
    2.5 50 0.26 2.2 7.6/7.8 0.28 3 –0.3 26
    3 45 0.31 2.4 6.15/6.36 0.32 3.4 –0.3 34
    4 56 0.31 2.75 4.71/4.85 0.32 3.7 –0.3 42
    5 65 0.33 3.1 3.94/4.02 0.32 4.2 -0.3 52
    6 84 0.31 3.3 3.14/3.23 0.32 4.3 –0.3 61
    8 50 0.46 4.3 2.38/2.52 0.32 5 -0.4 87
    10 80 0.41 4.5 1.82/1.85 0.48 5.8 –0.4 108
    12 96 0.41 5.4 1.52/1.6 0.48 6.5 -0.7 122
    16 126 0.41 5.5 1.16/1.18 0.52 7 –0.5 170
    20 152 0.41 6.9 0.955/0.999 0.52 7.8 -0.8 194
    25 196 0.41 7 0.743/0.757 0.52 8.7 –0.8 265
    X Allows nominal values and tolerances for the number of strands ≥ 6.0 mm² (±5%).
    XX This cross-section, featuring tinned stranded conductors, is suitable for insulation displacement connectors.
    XXX can also provide resistance values of 52.0/53.1 mΩ/m for bare/tinned wires.