Temperature range: -40℃ to +80℃ Structure/Materials: Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to D 609-90; the bare conductor structure complies with JASO D 611:2009. Insulation: Polyvinyl chloride; the insulation material complies with JASO D 611:2009. Standards/Specifications: Japanese Standards: JASO D 611:2009, JASO D 618:2008, JIS C 3406

Still hesitating? Just get a sample and contact us!

  • Product Details
  • Product Name
    PRODUCT Name

     

    AV polyvinyl chloride insulation

     

    Product Applications
    PRODUCT APPLICATION

     

    Automotive wiring, with PVC being the primary insulating material, is typically used in ambient-temperature areas of automotive body wire harnesses.

     

    Technical Parameters
    Technical parameter

     

    Temperature range: -40℃ to +80℃
    Structure/Material:
    Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to D 609-90; the bare conductor structure complies with JASO D 611:2009.
    Insulation: Polyvinyl chloride; insulation material complies with JASO D 611:2009.
    Standards/Specifications: Japanese Standards: JASO D 611:2009, JASO D 618:2008, JIS C 3406

     

    Cross-sectional area Conductor Construction Insulation Wire
    Number of conductor strands Conductor outer diameter
    Maximum value
    Stranded outer diameter
    Maximum value
    Conductor at 20℃
    DC resistance
    Thick skin Outer diameter Approximate weight
    Maximum value Tolerance
    square millimeters   mm mm mΩ/m mm mm mm kg/km
    0.5 7 0.32 1.0 32.7 0.60 2.4 –0.2 10
    0.85 11 0.32 1.2 20.8 0.60 2.6 –0.2 13
    1.25 16 0.32 1.5 14.3 0.60 2.9 –0.2 17
    2 26 0.32 1.9 8.81 0.60 3.4 –0.3 26
    3 41 0.32 2.4 5.59 0.70 4.1 –0.3 40
    5 65 0.32 3.0 3.52 0.80 4.9 –0.3 62
    8 50 0.45 3.7 2.32 0.90 5.8 –0.3 92
    10 63 0.45 4.5 1.84 1.00 6.9 –0.4 120
    15 84 0.45 4.8 1.38 1.10 7.4 –0.4 160
    0.5X 20 0.18 1.0 36.7 0.60 2.4 –0.2 9
    0.75X 30 0.18 1.2 24.4 0.60 2.6 –0.2 12
    1.25fX 50 0.18 1.5 14.7 0.60 2.9 –0.2 18
    2fX 37 0.26 1.8 9.5 0.60 3.4 –0.4 25
    3fX 61 0.26 2.4 5.76 0.70 4.1 –0.3 40
    In X-rated cross-section columns, the “f” indicates a flexible conductor with a thinner wire diameter.