Robotic arm communication cable

Suitable for installation in torsion and bending stress at the same time, with high flexibility, bending resistance, torsion resistance, wear resistance, oil resistance. Effective resistance to electromagnetic interference, twisted-pair pitch break, excellent crosstalk resistance

所属分类:

关键词:

Robotic arm communication cable

Product Detail

pic

PRODUCT INFORMATION

Product Name

 

Robotic arm communication cable

 

Product Application

 

Suitable for installation in high-speed signal loop, as control and monitoring signal transmission and power connection, installed in a variety of bending conditions.

 

Technical Parameter

 

Operating temperature range:
Fixed installation: -50℃~+90℃
Mobile installation: -40℃~+90℃

Rated voltage: S<0.5mm2:300/300V;
S>0.5mm2: 300/500V
Pressure test: 1500V/5min (300V/500V)                  Reference standard: TUV 2 PfG 2577

                                                                         
                 2000V/5min(450/750V)               Reference standard: TUV 2 PfG 2577                                                      

Bending test (robot body cable) :

90° bending test above 4mm2: ±90°,R=2.5D,F=5N,40 times/min, requirements > 1 million times Reference standard: TUV 2 PfG 2577 Annex F

Bending test less than 4mm2 (double pulley bending test) : moving speed 0.33m/s, travel =1m, required > 1,000,000 times Reference standard: §6.2 of EN50396

Torsion test (robot body cable) : ±180°,12 times/min, requirements > 500,000 times Reference standard: TUV:2 PfG 2577 Annex H

Bending and rotation test :R=150mm,L=300mm,50 times/min, > 50,000 times Reference standard: 2 PfG 2577/08.16 Annex C

2D linear torsion test :±90° or ±180°, 60 times/min, F=5N, requirement > 5 million times Reference standard: 2 PfG 2577/08.16 Annex G
2D curve torsion test :±90° or ±180°, 60 times/min, F=5N, requirement > 5 million times Reference standard: 2 PfG 2577/08.16 Annex G

3D torsion test :±180°, 30 times/min, requirement > 5 million times        Reference standard: 2 PfG 2577/08.16 Annex I

Towing chain test :±180°,12 times/min, requirement > 10 million times        Reference standard: 2 PfG 2577/08.16 Annex H

Flame retardant: in line with IEC60332-1-2+EN60332-1-2
Oil resistance: in accordance with DIN VDE0282

Minimum bending radius:
Fixed installation: 4×D (cable diameter);
Mobile installation: 6×D (cable outer diameter) when travel <10 meters, 8×D (cable outer diameter) when travel ≥10 meters
Mobile characteristics: laying stroke: >80m; Acceleration 65m/S2; Moving speed 12m/S Electrical parameters:

Recommended to comply with safety regulations: UL2589