  • 耐扭转机器人电线.jpg

Anti Torsion Robotic arm control cable

As a power control and signal transmission, PUR outer sheathed anti-distortion cable is suitable for installation in the situation where torsion and bending stress exist at the same time. It has high flexibility, bending resistance, torsion resistance, wear resistance and oil resistance. Resistant to torsion ±180 degrees of 10 million times of continuous core characteristics, also used in welding robot and manipulator connection and assembly, and connection rotary or lifting table

所属分类:

关键词:

Anti Torsion Robotic arm control cable

Product Detail

pic

PRODUCT INFORMATION

Product Name

 

Anti Torsion Robotic arm control cable

 

Product Application

 

Suitable for installation in torsion and bending stress at the same time, with high flexibility, bending resistance, torsion resistance, wear resistance, oil resistance. Resistant to torsion ±180 degrees, can also be used in welding robot and manipulator connection and assembly, and connection rotary or lifting table

 

Technical Parameter

 

Operating temperature range:
Fixed installation: -50℃~+90℃
Mobile installation: -40℃~+90℃

Rated voltage: S<0.5mm2:300/300V;
S>0.5mm2: 300/500V
Pressure test: 1500V/5min (300V/500V)                  Reference standard: TUV 2 PfG 2577

                                                               
                 2000V/5min(450/750V)                  Reference standard: TUV 2 PfG 2577                                                      

Bending test (robot body cable) :

90° bending test above 4mm2: ±90°,R=2.5D,F=5N,40 times/min, requirements > 1 million times Reference standard: TUV 2 PfG 2577 Annex F

Bending test less than 4mm2 (double pulley bending test) : moving speed 0.33m/s, travel =1m, required > 1,000,000 times Reference standard: §6.2 of EN50396

Torsion test (robot body cable) : ±180°,12 times/min, requirements > 500,000 times            Reference standard: TUV:2 PfG 2577 Annex H

Bending and rotation test :R=150mm,L=300mm,50 times/min, > 50,000 times            Reference standard: 2 PfG 2577/08.16 Annex C

2D linear torsion test :±90° or ±180°, 60 times/min, F=5N, requirement > 5 million times Reference standard: 2 PfG 2577/08.16 Annex G
2D curve torsion test :±90° or ±180°, 60 times/min, F=5N, requirement > 5 million times Reference standard: 2 PfG 2577/08.16 Annex G

3D torsion test :±180°, 30 times/min, requirement > 5 million times            Reference standard: 2 PfG 2577/08.16 Annex I

Towing chain test :±180°,12 times/min, requirement > 10 million times             Reference standard: 2 PfG 2577/08.16 Annex H

Flame retardant: in line with IEC60332-1-2+EN60332-1-2
Oil resistance: in accordance with DIN VDE0282

Minimum bending radius:
Fixed installation: 4×D (cable diameter);
Mobile installation: 6×D (cable outer diameter) when travel <10 meters, 8×D (cable outer diameter) when travel ≥10 meters
Mobile characteristics: laying stroke: >80m; Acceleration 65m/S2; Moving speed 12m/S Electrical parameters:

Recommended to comply with safety regulations: UL2517,UL2586