Product Series
High-flexibility robot cable
Still hesitating? Just get a sample and contact us!
- Product Details
-
Product NamePRODUCT Name
High-flexibility robot cable
Product ApplicationsPRODUCT APPLICATIONSuitable for installation in applications where torque and bending stresses coexist, this product features high flexibility, excellent resistance to bending, torsion, wear, and oil. It can withstand torsional angles ranging from ±180° to 360° and 720°. It is also ideal for connections and assemblies in robots and robotic arms, as well as in wind energy systems.
Technical ParametersTechnical parameterOperating temperature range:
Fixed installation: -50℃~+90℃
Mobile installation: -40℃ to +90℃Rated voltage: S < 0.5 mm²: 300/300 V;
S > 0.5 mm²: 300/500 V
Withstand Voltage Test: 1500V/5min (300V/500V) Reference Standard: TUV 2 PfG 2577
2000V/5min (450/750V) Reference standard: TUV 2 PfG 2577Bending test (robot body cable):
4 mm² and above, 90° bending test: ±90°, R = 2.5D, F = 5N, 40 cycles/minute; requirement: >1 million cycles. Reference standard: TUV 2 PfG 2577 Annex F
Bending test for conductors with cross-sectional area of 4 mm² or less (double-pulley flexural test): Moving speed 0.33 m/s, stroke length = 1 m, requirement > 1 million cycles. Reference standard: EN50396 §6.2.
Torsion Test (Robot Body Cable): ±180°, 12 cycles/minute, with a requirement of >500,000 cycles. Reference Standard: TUV: 2 PfG 2577 Annex H
Bending and Rotational Testing: R = 150 mm, L = 300 mm, 50 cycles/min, > 50,000 cycles Reference Standard: 2 PfG 2577/08.16 Annex C
2D Torsion Test for Straight Lines: ±90° or ±180°, 60 cycles/min, F = 5 N; requirement: > 5 million cycles. Reference standard: 2 PfG 2577/08.16 Annex G
2D Curved Torsion Test: ±90° or ±180°, 60 cycles/min, F = 5 N; requirement: > 5 million cycles. Reference standard: 2 PfG 2577/08.16 Annex G3D Torsion Test: ±180°, 30 cycles/minute, with a requirement of >5 million cycles Reference Standard: 2 PfG 2577/08.16 Annex I
Drag chain test: ±180°, 12 cycles/minute, requirement > 10 million cycles Reference standard: 2 PfG 2577/08.16 Annex H
Flame Retardancy: Complies with IEC60332-1-2 + EN60332-1-2
Oil resistance: Complies with DIN VDE0282Minimum bending radius:
Fixed installation: 4×D (cable outer diameter);
Mobile installation: For travel distances less than 10 meters, use 6 × D (cable outer diameter); for travel distances of 10 meters or more, use 8 × D (cable outer diameter).
Mobile characteristics: Laying travel distance: >80m; Acceleration: 65m/s²; Moving speed: 12m/s Electrical parameters:Recommendation complies with safety regulations:
Recommended Products