• 60227 IEC 06 (RV) type cable
60227 IEC 06 (RV) type cable
+

60227 IEC 06 (RV) type cable

Rated voltage: 300/500V Structure: Conductor: Number of cores: 1 core; the conductor complies with the requirements for Class 5 conductors specified in GB/T3956-1997. Insulation: The insulation extruded onto the conductor shall be a PVC/C-type polyvinyl chloride compound. The insulation thickness shall conform to the values specified in Column 2 of the table below. The insulation resistance shall not be less than the values specified in Column 5 of the table below.

Still hesitating? Just get a sample and contact us!

  • Product Details
  • Product Name
    PRODUCT Name

     

    60227 IEC 06 (RV) type cable

     

    Product Applications
    PRODUCT APPLICATION

     

    RV cable wires are widely used in the industrial power distribution field, particularly well-suited for flexible installation environments with stringent requirements—such as electrical control cabinets, distribution boxes, and various low-voltage electrical equipment. They can be used to transmit power, electrical control signals, and switch signals. RV wire and cable feature a soft-construction design with a small conductor bending radius, making them ideal for installation environments that are damp and oily. Moreover, RV cable wires have obtained both CCC and CE certifications and meet the requirements of HD (the harmonized European standard). As a result, they are not only suitable for the Chinese market but also for the European market.

     

    Technical Parameters
    Technical parameter

     

    Rated voltage: 300/500V
    Structure:
    Conductor: Number of cores: 1 core; the conductor meets the requirements specified for Type 5 conductors in GB/T3956-1997.
    Insulation:
    The insulation extruded onto the conductor shall be a PVC/C-type polyvinyl chloride compound.
    The insulation thickness shall comply with the values specified in Column 2 of the table below. The insulation resistance shall be no less than the values specified in Column 5 of the table below.

     

    Conductor nominal
    Cross-sectional area/mm²
    Insulation thickness
    Specified value/mm
    Average outer diameter/mm Minimum at 70 ℃
    Insulation resistance /
    (MQ ·km)
    Lower limit Upper limit
    0.5 0.6 2.1 2.5 0.013
    0.75 0.6 2.2 2.7 0.0113
    1 0.6 2.4 2.8 0.010